HYPERLAB PLUS wine analyzer

Contact our expert for more informations.

Request information

Hyperlab wine analyzer represents the most advanced solution for analytical control automation in the oenological field
Over 500 installations and 15 years of quality and reliability in the best enological laboratories!
The results of the analyses are extremely accurate and permit the user to work in an extremely time-efficient manner thus allowing for both quality analysis improvement and cost-benefit optimization.

Hyperlab is an automatic multi-parametric analyzer with Flexible Random Access, i.e. it can fully perform all the manual operating procedures automatically.

The sampling arm, controlled by a microprocessor, takes the wine sample, dilutes it (if necessary), and adds the required reagents. The sample and reagents are mixed in a reaction cuvette, where they remain at a constant temperature until the reaction is complete.

The result of the reaction is read at a specific wavelength, and the recorded absorbance is converted into concentration using calculation algorithms.

 

Benefits

  • BEST QUALITY AND ECONOMICAL

    Hyperlab automation guarantees the greatest data results accuracy and precision, thus significantly reducing analysis costs by about seven times when compared with manual methodologies.

    With Hyperlab reagents are reduced to minimum: a single determination requires less than 300 microlitres.

  • METHODS IN MEMORY

    Acetic acid, Citric acid, D-Gluconic acid, D-Lactic acid, L-Lactic acid, L-Malic acid, Pyruvic acid, Tartaric acid, Acetaldehyde, Anthocyanin, Alpha Amino nitrogen, Ammoniacal nitrogen, Calcium, Catechins, Chlorides, Iron, Glycerol, Glucose/Fructose, Glucose/Fructose (for high sugar concentration analysis on musts), Magnesium, Total polyphenols, Potassium, Copper, Free and Total SO2, Optical reference solution.

    Other methods:

    IC (colour intensity 420+520), shade (420/520), ICM (modified colour intensity 420+520+620), GRB (% yellow, red and blue colour on total colour. This is an indispensable determination for products undergoing refining or micro-oxygenation process).

    The optical reference solution gives the technical specifications of the instrument regardless its kit performances.

    The best way to demonstrate Hyperlab precision is the use of bicromatic optical solution (suggested by IUPAC - International Union of Pure and Applied Chemistry).
     

  • Calibrations

    Reagent blank subtraction, 1 to 8 calibrators for single test. Linear and non-linear regressions with three types of data extrapolation: cubic, polynomial and log-logit.

  • Innovative software and hardware

    Innovative software: Windows system, user-friendly functions, touch screen technology, switch-on/off with programmable start-up, on-line support.

    Monitor: Information on programmed methods, selected analyses, n° of analyses to be run, calibration and check status.

    Reagent panel: Displays the samples position and their volumes.

    Samples: Samples status display. Possibility of adding, removing or modifying samples during the analysis.

    Working lists: Unlimited working lists can be used simultaneously. Tests may be added or removed and automatically repeated if wrong. Inspection of kinetics reaction can be performed for single tests.

  • Data processing and Tests

    Data processing

    Results can be re-calculated at the end of the analysis by correlating them to one or more samples with fixed value. The new regression line will show the value obtained by the re-calculation.



    Tests

    All the analyses regarding a spectrophotometric determination can be automatized.
     

Technical features

VOLUMES 
Sample: 2-300µl, precision 1% at 10µl
Reagent: 5-350 µl, precision < 1% at 250µl
Reaction (sample + reagent): 220-350µl
Mixing in cuvette after dispensation

DILUTION
Automatic programmable dilution for each sample
Factors: 1:1, 1:4, 1:10, 1:40, 1:100

ANALYTICAL SPEED
125...200 analyses/hour - Hyperlab Plus
100...180 analyses/hour - Hyperlab Basic

TEMPERATURE CONTROL 
Refrigerated reagent at 15°C below ambient temperature
Reading cuvette with programmable heating
Reagent preheating in sucking needle

TYPES OF TESTS 
Endpoint, Bichromatic endpoint, Differential endpoint, Differential endpoint sample blank, Derivatives, Fixed time, Kinetic.

SAMPLES TRAY: 60 samples positions

REAGENTS TRAY: 30 positions refrigerated tray

SAMPLING NEEDLE: Glass ceramics stroke needle, capacitance sensor, reagent pre-heating 

REACTION CUVETTE ROTOR: 80 BIONEX® cuvettes replaceable singularly, over 20.000 tests

WASHING STATION: 6 dispensing needles for washing solution, 6 sucking needles, 1 drying needle, 8 washing cycles for each cuvette

OPTICAL GROUP
1 halogen lamp (6V, 10W) with extended UV emission, 2 focusing lenses, 10-position interference filters, 8 positions provided with interference filters of 340, 420, 520, 546, 578, 620, 650, 700 mm, 1 free position and 1 for dark reading.

DATA RE-PROCESSING 
Results can be re-calculated at the end of the analysis by correlating them to one or more samples with fixed value

INNOVATIVE SOFTWARE 
Extremely user-friendly. Optimized random system allows the user to work efficiently and comfortably. Operating system: Windows
2x20lt plastic tanks for washing and discharge water- Hyperlab Plus
2x5lt plastic tanks for washing and discharge water- Hyperlab Basic

SAFETY SHIELD SENSOR on request

DIMENSIONS: LxDxH 60x66x50 cm

WEIGHT: 38Kg 

The sampling arm, controlled by a microprocessor, carries out the sample taking, its dilution (if required by the method) and the reagents suction. Both the sample and the reagents are dispensed in the reaction cuvette and remain there long enough, under constant and controlled temperature, to allow for a reaction to fully take place.

The reaction product is given by means of a preset wavelenght and the absorbance obtained is expressed in a concentration value with appropriate algorithms. During the process the washing phases take place between the aspiration and dispensation cycles, thus avoiding any contamination risks between the reagents and samples. After the cuvette is dried, it undergoes an accurate optical control before a new analysis is run.

Industries
Food
Oenological
Pharmaceutical
Applications
Food analysis
Wine analysis
Enzymatic analysis
Multiparametric Analysis
Fermentation

Product codes

Steroglass code Brand code Description
SQRQ060129 HYPERLAB Hyperlab plus wine analyzer
You could be interested in